Human Interleukin 1α (IL-1α) ELISA Kit

Human Interleukin 1α (IL-1α) ELISA Kit | High‑Sensitivity Sandwich Assay

Product Code: YD-H-IL-1α
Application: Quantitative determination of Human Interleukin 1α (IL-1α) concentration in serum, plasma, cell culture supernatants, and tissue homogenates.
Detection Range: 10 – 800 pg/mL (optimised)
Sensitivity: < 10 pg/mL
Sample Volume: 50 μL
Total Assay Time: ~1.5 hours
Storage: 2–8 °C, protect from light
Format: 96‑well pre‑coated strip plate (8 wells × 12 strips) or 48‑well format (8 wells × 6 strips)
Precision: Intra‑assay CV < 5 %; Inter‑assay CV < 8 %

Product Overview: Why Measure IL‑1α?

Interleukin 1α (IL‑1α) is a potent pro‑inflammatory cytokine belonging to the IL‑1 family. It is produced by activated macrophages, monocytes, epithelial cells, and many other cell types. Unlike IL‑1β, IL‑1α is primarily cell‑associated and acts as a danger signal released upon cell damage or necrosis, playing a critical role in sterile inflammation, fever, and tissue repair. Dysregulated IL‑1α levels are implicated in rheumatoid arthritis, psoriasis, inflammatory bowel disease, atherosclerosis, and cancer. Accurate quantification of Human Interleukin 1α (IL‑1α) is essential for:

  • Inflammation and autoimmune disease research
  • Cardiovascular and atherosclerosis studies
  • Cancer immunology and tumour microenvironment investigations
  • Drug development targeting the IL‑1 pathway

Why Choose Yanda Bio as Your ELISA Test Kit Manufacturer & ELISA Diagnostic Kit Supplier?

EEAT FactorOur Commitment
Experience6,000+ factors developed; 60+ university collaborations; years of expertise in cytokine and inflammatory assays.
ExpertiseProprietary antibody pairs validated for human IL‑1α; sandwich ELISA design ensures high specificity and minimal cross‑reactivity with IL‑1β, IL‑1Ra, or other interleukins.
AuthoritativenessKits used in academic publications; ISO‑aligned manufacturing; batch‑to‑batch consistency.
TrustworthinessTransparent specifications; rapid custom development (3–7 days); unconditional quality guarantee; free shipping on 3+ kits.

As a trusted ELISA test kit manufacturer and reliable elisa diagnostic kit supplier, Yanda Bio delivers premium quality at factory‑direct prices.

Superior Quality Metrics

  • Intra‑assay CV < 5 % — excellent within‑run precision
  • Inter‑assay CV < 8 % — outstanding run‑to‑run consistency
  • High specificity — no cross‑reactivity with human IL‑1β, IL‑6, TNF‑α, or other cytokines

Kit Components: What’s Inside (96T / 48T)

Component96‑Well Configuration48‑Well Configuration
Microplate (Pre‑coated)8 wells × 12 strips8 wells × 6 strips
Standards0.3 mL × 6 tubes0.3 mL × 6 tubes
Sample Diluent6 mL3 mL
HRP‑Conjugated Detection Antibody6 mL3 mL
20× Wash Buffer25 mL15 mL
Substrate A6 mL3 mL
Substrate B6 mL3 mL
Stop Solution6 mL3 mL
Plate Sealer2 sheets2 sheets
Manual1 copy1 copy

96T kit is sufficient for 85 samples (in duplicate); 48T kit is sufficient for 37 samples (in duplicate).


Assay Principle: Sandwich ELISA

This kit employs a solid‑phase sandwich enzyme‑linked immunosorbent assay. The microplate is pre‑coated with a monoclonal antibody specific for Human IL‑1α. Standards and samples are added, allowing IL‑1α to bind to the immobilised antibody. After washing, a Horseradish Peroxidase (HRP)‑conjugated detection antibody is added, forming an antibody‑antigen‑antibody “sandwich”. Following a second wash, TMB substrate is added. The HRP enzyme catalyses a blue colour that turns yellow upon acidification. The optical density (OD) at 450 nm is directly proportional to the IL‑1α concentration in the sample.


Sample Collection & Preparation

Sample TypeCollection & Processing
SerumUse pyrogen/endotoxin‑free tubes. Avoid cell stimulation. Centrifuge at 3000 rpm for 10 minutes.
PlasmaUse EDTA, citrate or heparin anticoagulant. Centrifuge at 3000 rpm for 30 minutes.
Cell SupernatantCentrifuge at 3000 rpm for 10 minutes to remove particles.
Tissue HomogenateHomogenise tissue in PBS (1:9 w/v), centrifuge at 5000×g for 10 minutes at 2–8 °C. Collect supernatant.
StorageAliquot and store at –20 °C (≤ 1 month) or –80 °C (≤ 2 months). Avoid repeated freeze‑thaw cycles.

Materials Required But Not Provided

  1. Microplate reader (450 nm)
  2. Precision pipettes and tips (0.5–10 μL, 2–20 μL, 20–200 μL, 200–1000 μL)
  3. 37 °C incubator or water bath
  4. Distilled or deionised water

Important Notes for Assay Procedure

  1. Store the kit at 2–8 °C. Bring all reagents to room temperature for 20 minutes before use. Concentrated wash buffer may crystallise; dissolve crystals in a warm water bath.
  2. Return unused strips to the resealable bag with desiccant and store at 2–8 °C. Use promptly.
  3. The S0 standard (zero concentration) is the negative control/blank.
  4. Strictly adhere to incubation times, temperatures, volumes and sequence.
  5. Avoid letting microplate wells dry out during incubation.
  6. If sample concentration is expected to be very high, dilute samples appropriately and multiply final results by the dilution factor.
  7. For large numbers of samples, use a multi‑channel pipette to keep addition time within 5 minutes.

Reagent Preparation

20× Wash Buffer Dilution: Dilute 1 part 20× wash buffer with 19 parts distilled water to obtain 1× working wash buffer.


Washing Method

Manual: Aspirate liquid, fill each well with wash buffer (350 μL), stand for 1 min, aspirate, and tap dry on absorbent paper. Repeat 5 times. Incomplete washing may cause false positives.

Automatic washer: Inject 350 μL per well, soak for 1 min, wash 5 times.


Assay Procedure

  1. Remove required strips after 20 min equilibration. Reseal unused strips and return to 4 °C.
  2. Standard wells: add 50 μL of each standard concentration.
  3. Sample wells: add 50 μL of test sample. Blank wells: leave empty.
  4. Add 100 μL HRP‑conjugated detection antibody to all wells except blanks. Seal and incubate at 37 °C for 60 min.
  5. Aspirate, wash 5 times (manual or automatic).
  6. Add 50 μL Substrate A and 50 μL Substrate B to each well. Incubate at 37 °C in the dark for 15 min.
  7. Add 50 μL stop solution. Measure OD at 450 nm within 15 min.

Note: Run standards and samples in duplicate for best accuracy.Common Issues with Experimental Samples in Human Interleukin ELISA Kits


Data Analysis

Plot standard curve: OD values (y‑axis) vs. standard concentrations (x‑axis) using linear regression (R ≥ 0.9900). Calculate sample concentrations directly from the curve. If samples were diluted, multiply by the dilution factor.


Kit Performance Specifications

ParameterPerformance
AccuracyStandard curve linear regression coefficient (R) ≥ 0.9900
SensitivityMinimum detectable concentration < 10 pg/mL
Detection Range10 – 800 pg/mL (optimised; range may be adjusted upon request)
SpecificityNo cross‑reactivity with human IL‑1β, IL‑6, TNF‑α, IL‑4, IL‑10, or other cytokines
Intra‑assay CV< 5 %
Inter‑assay CV< 8 %
Storage2–8 °C, protect from light and moisture
Shelf Life6 months

Pricing & Shipping Information

QuantityPrice per Kit
1–2 kits$120 (retail)
3 or more kitsWholesale price – contact us for a quote

Free shipping on all orders of three or more ELISA kits. All products are tax‑inclusive and delivered to your doorstep.


Related Products (Recommended for Cytokine Studies)

Expand your inflammation research with these complementary kits (available from Yanda Bio):

  • Rabbit Interleukin 13 (IL‑13) ELISA Kit – for Th2 immune response studies in rabbit models
  • Human Interleukin 1β (IL‑1β) ELISA Kit – to differentiate between IL‑1α and IL‑1β pathways in human inflammation

Using IL‑1α together with IL‑1β provides a complete picture of the IL‑1 family signalling.


Why Yanda Bio is Your Preferred ELISA Test Kit Manufacturer & elisa diagnostic kit supplier

  • Manufacturer direct – over 6,000 detectable targets, 60+ university partners
  • Rapid custom development – 3–7 days turnaround for new targets or matrices
  • Strict quality control – intra‑assay CV < 5 %, inter‑assay CV < 8 %
  • Cost‑effective – premium performance at 40–60 % lower cost than leading international brands
  • Free technical support – from sample collection to data analysis
  • Free sample testing service – available upon request (contact our sales team)

Comprehensive species and target coverage:
Human, rat, mouse, rabbit, monkey, pig, horse, chicken, duck, goat, fish, and more.
Assay types: Cytokines, myocardial infarction markers, endocrinology, liver fibrosis, autoimmunity, tumour markers, infectious diseases, specific proteins, prenatal screening, etc.


Disclaimer

Strict adherence to the protocol is required. Yanda Bio is not responsible for results obtained from deviations. This product is for research use only; not for clinical diagnosis or human use. The user assumes all responsibility for any consequences arising from misuse.


Ordering & Contact Information

To order this Human Interleukin 1α (IL‑1α) ELISA Kit, or to inquire about volume discounts, custom development, and format selection, please contact our sales team.

You May Also Like

Mouse Interleukin 6 (IL-6) ELISA Kit

Mouse Interleukin 6 (IL-6) ELISA Kit

Detection Range: 32 – 2000 pg/mL
Storage: 2–8 °C, protect from light
Precision: Intra‑assay CV < 5 %
Porcine Interleukin 28B (IL-28B) ELISA Kit

Customized Porcine Interleukin 28B (IL-28B) ELISA Kit

Detection Range: 32 – 2000 pg/mL
Sensitivity: < 10 pg/mL (optimised)
Precision:Inter‑assay CV < 8 %
Human Syndecan‑4 (SDC‑4) ELISA Kit

Human Syndecan‑4 (SDC‑4) ELISA Kit

Sensitivity: < 1.0 μg/mL
Total Assay Time: ~1.5 hours
Storage: 2–8 °C, protect from light